info@damimedical.com
Anesthesia Use Double Lumen Laryngeal Mask
HOME » Products » Laryngeal Masks » Anesthesia Use Double Lumen Laryngeal Mask
Problems of current laryngeal mask airway
Compared to endotracheal (ET) tubes, Supraglottic LMAs provide more comfortable ventilation with reduced pharyngeal trauma. However, existing laryngeal masks present inherent limitations in clinical practice. As an innovative laryngeal mask manufacturer, Dami Medical, through collaboration with leading anesthesiologists, has developed a next-generation silicone laryngeal mask airway with enhanced safety features.
While conventional LMAs incorporate a single drainage channel for gastric secretions, clinical studies indicate this design fails to adequately prevent regurgitation, with reflux incidence reaching up to 33%. This poses significant risks as aspiration of acidic gastric contents may compromise airway patency, cause mucosal damage, and trigger severe complications including bronchospasm, aspiration pneumonia, and in critical cases, respiratory failure. These safety concerns remain the predominant challenge in LMA-assisted anesthesia.
To address this critical issue, Dami’s innovative LMA features a dual-channel drainage system that effectively mitigates aspiration risks while maintaining optimal ventilation.
Dami double lumen silicone laryngeal mask
Innovative safer structure
Double reflux drainage channels
More comfortable design
Avoid nerve dense area
Better sealing and ventilation
Clinical proved sealing and ventilation performance
Specially safe for pediatric
Safer and comfortable for Children use
Safer structure
Dami LMA supraglottic airway designed with double channels to guide gastroesophageal reflux, reduce the drainage pressure, prevent reflux regurgitation and aspiration, furtherly avoid complications effectively.
No.1: Back groove channel on the back of the laryngeal mask
No.2: Gastric tube channel
Soft Material and Slip Surface
The cuff, airway tube & inflation tube of the laryngeal mask airway are made by medical silicone material. Besides it is very soft with super smooth surface processing, less resistance and easy inserting.
Special comfortable design
We adopt special design to avoid nerve ending areas, thus less irritation to patients. Please feel free to contact us for more details.
Device History
Dami Double-Lumen Drainage Laryngeal Mask is developped by Doctor Xia Min, who is Deputy Chief Physician & Chief Innovation Officer CIO of The First Affiliated Hospital of University of Science and Technology of China (USTC).
“My aim was to make a safer device which can solve current device’s challenging reflux problem, and this innovation thanks to my 18 years clinical working experience.”
Now this new generation lma are using in over 300 hospitals.
Models
Ref. No. Size Weight of Patients Max.inflation volume Max. ET Tube
180021 1.0# Infant < 5kg 4ml /
180022 1.5# Infant 5-12kg 7ml 4.0#
180023 2.0# Child < 12-25kg 10ml 4.5#
180024 2.5# Child < 25-40kg 14ml 5.0#
180025 3.0# Adult < 40-65kg 20ml 6.0#
180026 4.0# Adult < 65-90kg 30ml 6.5#
180027 5.0# Adult > 90kg 40ml 7.0#